Specifications

9-23
Cisco ONS 15454 Installation and Operations Guide, R3.2
March 2002
Chapter 9 Ethernet Operation
E Series Circuit Configurations
Figure 9-18 A Hub and Spoke Ethernet circuit
Procedure: Provision an E Series Hub and Spoke Ethernet Circuit
Step 1 Display CTC for one of the ONS 15454 Ethernet circuit endpoints.
Step 2 Double-click the Ethernet card that will create the circuit.
Step 3 Click the Provisioning > Card tabs.
Step 4 Under Card Mode, check the Single-card EtherSwitch checkbox.
If Single-card EtherSwitch is not checked, check it and click Apply.
Step 5 Navigate to the other ONS 15454 endpoint and repeat Steps 2 – 4.
Step 6 Display the node view or network view.
Step 7 Click the Circuits tab and click Create.
The Circuit Creation (Circuit Attributes) dialog box opens.
Step 8 In the Name field, type a name for the circuit.
Step 9 From the Type pull-down menu, choose STS.
Note The types VT and VT Tunnel do not apply to Ethernet circuits.
Step 10 Choose the size of the circuit from the Size pull-down menu.
Step 11 Verify that the Bidirectional checkbox is checked and click Next.
The Circuit Creation (Circuit Source) dialog box opens.
Step 12 From the Node menu, choose the circuit source.
Either end node can be the circuit source.
Step 13 From the Slot menu, choose the Ethernet card where you enabled the single-card EtherSwitch and click
Next.
The Circuit Creation (Circuit Destination) dialog box opens.
Step 14 Choose the circuit destination from the Node menu.
43386
ONS Node 1
ONS Node 2192.168.1.25
255.255.255.0
VLAN test
192.168.1.50
255.255.255.0
VLAN test
192.168.1.125
255.255.255.0
VLAN test
192.168.1.75
255.255.255.0
VLAN test
192.168.1.100
255.255.255.0
VLAN test
ONS Node 3