Specifications

8-26
Cisco ONS 15454 Installation and Operations Guide, R3.2
March 2002
Chapter 8 Performance Monitoring
Performance Monitoring for Electrical Cards
STS FC-P
Near-End STS Path Failure Counts (FC-P) is a count of the number of
near-end STS path failure events. A failure event begins when an AIS-P
failure, an LOP-P failure, a UNEQ-P, or a TIM-P failure is declared. A
failure event also begins if the STS PTE that is monitoring the path
supports ERDI-P for that path. The failure event ends when these failures
are cleared.
STS SES-P
Near-End STS Path Severely Errored Seconds (SES-P) is a count of the
seconds when K (2400) or more STS path BIP errors were detected. An
AIS-P defect (or a lower-layer, traffic-related, near-end defect) or an
LOP-P defect can also cause an STS SES-P.
STS UAS-P
Near-End STS Path Unavailable Seconds (UAS-P) is a count of the
seconds when the STS path was unavailable. An STS path becomes
unavailable when ten consecutive seconds occur that qualify as SES-Ps,
and it continues to be unavailable until ten consecutive seconds occur that
do not qualify as SES-Ps.
Table 8-18 Near-End SONET Path PMs for the DS3 and DS3N Cards (continued)
Parameter Definition