Specifications

8-15
Cisco ONS 15454 Installation and Operations Guide, R3.2
March 2002
Chapter 8 Performance Monitoring
Performance Monitoring for Electrical Cards
Figure 8-11 Monitored signal types for the EC1 card
Note The XX in the illustration above represents all PMs listed below with the given prefix and/or suffix.
Figure 8-12 PM read points on the EC1 card
Note SONET path PMs will not count unless IPPM is enabled. For additional information, see Enabling
Intermediate-Path Performance Monitoring, page 8-10. The far-end IPPM feature is not supported in
Software R3.0, R3.1, or R3.2. However, SONET path PMs can be monitored by logging into the
far-end node directly.
55310
ONS 15454
EC1 OC48
Fiber
Near End
EC1 Signal
EC1 Path (EC1 XX) Far End PMs Not Supported
ONS 15454
EC1OC48
Far End
EC1 Signal
STS Path (STS XX-P) Far End PMs Not Supported
55304
ONS 15454
EC1 Card
LIU
Framer
BTC
Tx/Rx
XC10G Card OC-N
Line Side
Path
Level
SONET Side
STS CV-P
STS ES-P
STS FC-P
STS SES-P
STS UAS-P
CV-S
ES-S
SES-S
SEFS-S
CV-L
SES-L
ES-L
UAS-L
FC-L
PPJC-Pdet
NPJC-Pdet
PPJC-Pgen
NPJC-Pgen
PMs read on Framer