Specifications
7-5
Cisco ONS 15454 Installation and Operations Guide, R3.2
March 2002
Chapter 7 Card Provisioning
Provisioning Electrical Cards
Elect Path
Thrshld
ES Errored seconds Numeric. Defaults:
• 65 (15 minutes)
• 648 (1 day)
SES Severely errored seconds Numeric. Defaults:
• 10 (15 minutes)
• 100 (1 day)
SAS Severely errored frame/alarm
indication signal
Numeric. Defaults:
• 2 (15 minutes)
• 17 (1 day)
AIS Alarm indication signal Numeric. Defaults:
• 10 (15 minutes)
• 10 (1 day)
UAS Unavailable seconds Numeric. Defaults:
• 10 (15 minutes)
• 10 (1 day)
SONET
Threshold
CV Coding violations Numeric. Defaults:
• 15 (15 minutes)
• 125 (1 day)
ES Errored seconds Numeric. Defaults:
• 12 (15 minutes)
• 100 (1 day)
FC Failure count Numeric. Defaults (VT termination):
• 10 (15 minutes)
• 10 (1 day)
SES Severely errored seconds Numeric. Defaults:
• 3 (15 minutes)
• 7 (1 day)
UAS Unavailable seconds Numeric. Defaults:
• 10 (15 minutes)
• 10 (1 day)
Table 7-2 DS-1 Card Parameters (continued)
Subtab Parameter Description Options