User guide

PTP 800 Series User Guide Installing the link
phn-2513_004v000 (Oct 2012)
8-9
Installing the link
Perform this task if any problems are experienced with a newly installed (or operational)
wireless link.
Connect to the web management interface
See Connecting to the web management interface on page 8-2.
Check RFU status
RFU status is indicated by the RFU Status attribute in the Status screen of the web
interface.
Check the RFU Status attribute and take action as described in Table 270.
Table 270 RFU status checks
RFU Status attribute Likely cause and action
OK The RFU is available for use. Continue at
Transmitter status on page 8-10.
Download In Progress The CMU is downloading updated firmware to the
RFU. Wait for the download to complete.
No Response The RFU is not responding to management
messages from the CMU. Check connections and
continue at Testing the ODU and IF cable on page
5-60.
Power Supply Fault The CMU cannot power the RFU. Check
connections and continue at Testing the ODU and
IF cable on page 5-60.
RFU Fault The RFU is reporting a fault condition.
Incompatible Device
Incompatible Firmware Version
The RFU firmware is not compatible with the
CMU. Replace the RFU.