User guide
PTP 800 Series User Guide Connecting to the web management interface
phn-2513_004v000 (Oct 2012)
8-5
Check the copper Data port Ethernet connection
Check the state of the copper Data port indicators and take action as described in Table
267.
Table 267 Copper Data port indicator checks
Copper Data
port indicator
state
Likely cause and action
Yellow steady,
green steady
The Ethernet link is up but is not carrying traffic. Continue at
Check IP network connection on page 8-7.
Yellow blink,
green blink
The Ethernet link is up and is carrying traffic. Continue at Check
IP network connection on page 8-7.
Off The Ethernet link is down. Continue at Copper Data port
indicator is off on page 8-5.
Copper Data port indicator is off
If the Copper Data port indicator is off, it means that the Ethernet link is down.
If the CMU copper data port is connected to a network, check the following:
• The associated network equipment (workstation, PC, router, switch etc.) is powered up
and operating correctly.
• The Ethernet port in the associated equipment is enabled.
• The Ethernet cable between the CMU and the network equipment is connected and is
not damaged. If possible, substitute a known good Ethernet cable.
• The Ethernet ports have compatible auto negotiation and duplex settings as described
in Configuring the IP interface and management mode on page 6-10.
If the CMU Data port is connected directly to a PC, check the following:
• The Ethernet port in the PC is enabled.
• The Ethernet cable between the CMU and the PC is connected and is not damaged. If
possible, substitute a known good Ethernet cable.
• The Ethernet ports have compatible auto negotiation and duplex settings as described
in Configuring the IP interface and management mode on page 6-10.
If these steps fail to resolve the problem, continue at Using recovery mode on page 7-71,