User guide

PTP 800 Series User Guide Task 6: Configuring protection
phn-2513_004v000 (Oct 2012)
6-55
Before upgrading existing links from unprotected to protected, complete the following
prerequisites:
Configure the new CMUs as primary or secondary units by setting the Primary
Secondary Mode attribute.
For a new primary CMU, ensure that wireless transmission is disabled by selecting
Mute Transmitter. This prevents possible interference with the existing operational
unit.
Attach ‘Primary” or ‘Secondary’ labels as appropriate to the new CMUs.
Set Fault Protection Switching to ‘Disabled’. This prevents fault protection switches
occurring during installation.
To configure protection, proceed as follows:
1
Select menu option System, Configuration, Protection. The Protection
Configuration page is displayed (Figure 136).
2
If the Transmitter attribute is set to ‘Enabled’, there may be a safety
requirement to disable wireless transmission. If so, select Mute Transmitter.
The Transmitter attribute changes to ‘Muted’.
3
Depending on whether Receive Diversity is required, set the Primary unit
protection attribute to either ‘Hot Standby 1+1’ (Figure 137) or ‘Hot Standby
1+1 with Rx Diversity’ (Figure 138).
4
Repeat at the Secondary unit (Figure 139 or Figure 140):
5
Review and update the Protection Configuration attributes (Table 231).
6
Select Submit Updated configuration.