Attribute Meaning
Management Mode ‘Out-of-Band Local’ means that the web interface can be
reached from the management port at the local CMU only.
This mode allows the construction of a management network
that is isolated from the customer network. This is the default
mode. For more information, see Out-of-band local
management on page 1-44.
‘Out-of-Band’ means that the web interface can be reached
from the management port at both the local and remote CMUs
(assuming that the wireless link is established). For a 1+1 Hot
Standby link, configuration access to the remote inactive unit
requires connectivity between the management ports. For
more information, see Out-of-band management on page 1-44.
If ‘Out-of-Band’ is selected, remember to set the Management
Committed Information Rate (Table 224).
‘In-Band’ means that the web interface can be reached from
the data port at both the local and remote CMUs (assuming
that the wireless link is established). In this mode, the
management port is disabled. For a 1+1 Hot Standby link,
connectivity must be provided between the CMU data ports by
the customer’s network. For more information, see In-band
management on page 1-45.
For in-band and out-of-band remote management after
installation, all four units providing a 1+1 Hot Standby link
are accessible from the user interface of each unit.