User guide
PTP 800 Series User Guide Network management specifications
phn-2513_004v000 (Oct 2012)
4-79
Object identifier Object name
.1.3.6.1.2.1.17.1.2 dot1dBaseNumPorts
.1.3.6.1.2.1.17.1.3 dot1dBaseType
.1.3.6.1.2.1.17.4.1.1 dot1dBasePort
.1.3.6.1.2.1.17.4.1.2 dot1dBasePortIfIndex
.1.3.6.1.2.1.17.4.1.3 dot1dBasePortCircuit
.1.3.6.1.2.1.17.4.1.4 dot1dBasePortDelayExceededDiscards
.1.3.6.1.2.1.17.4.1.5 dot1dBasePortMtuExceededDiscards
Interfaces
The standard interface MIB for PTP 800 always reports five interfaces as follows:
Table 203 Identification of interfaces
ifIndex ifDescr ifType ifOperStatus
1 wireless interface propWirelessP2P(157) up | down
2 ethernet data interface ethernetCsmacd(6) up | down
3 ethernet management interface ethernetCsmacd(6) up | down
4 telecom channel A interface ds1(18) notPresent
5 telecom channel B interface ds1(18) notPresent
PTP 800 does not support telecom channels. These interfaces are included for
consistency with other Cambium PTP products.
Counters
The tables below demonstrate the relationship between counter objects in the standard
MIB and attributes on the Detailed Counters page of the web-based management
interface:
Table 204 Counters for the wireless interface
MIB object Detailed counter in the web-based interface
ifInUcastPkts WirelessDataRxFrames + WirelessManagementRxFrames
ifInDiscards Sum of WirelessDataRxFramesDiscardedQ
n