• 32 GHz: Table 54.
• 38 GHz: Table 55.
If ODU-B is available (11, 18 and 23 GHz), choose it in preference to ODU-A. Do not
install ODU-A and ODU-B in the same link.
Table 40 ODUs: Lower 6 GHz ODU-A
Cambium part
number
Standard Sub-
band
Sub-band frequency T/R
spacing
01010411007 FCC,
ETSI
B1-Lo 5925 – 6025 MHz 252
MHz
01010411008 B1-Hi 6175 – 6275 MHz
01010411009 B2-Lo 6000 – 6100 MHz
01010411010 B2-Hi 6250 – 6350 MHz
01010411011 B3-Lo 6075 – 6175 MHz
01010411012 B3-Hi 6325 – 6425 MHz
Table 41 ODUs: Upper 6 GHz ODU-A
Cambium part
number
Standard Sub-
band
Sub-band frequency T/R
spacing
01010411024 FCC B1-Lo 6580 – 6640 MHz 160
MHz
01010411022 B1-Hi 6740 – 6800 MHz
01010411025 B2-Lo 6640 – 6710 MHz
01010411023 B2-Hi 6800 – 6870 MHz
01010411027 FCC B1-Lo 6530 – 6580 MHz 170
MHz
01010411026 B1-Hi 6700 – 6750 MHz
01010411013 ETSI B1-Lo 6430 – 6540 MHz 340
MHz
01010411014 B1-Hi 6770 – 6880 MHz
01010411015 B2-Lo 6520 – 6630 MHz
01010411016 B2-Hi 6860 – 6970 MHz
01010411017 B3-Lo 6600 – 6710 MHz
01010411018 B3-Hi 6940 – 7050 MHz
01010411019 B4-Lo 6670 – 6780 MHz
01010411020 B4-Hi 7010 – 7120 MHz