Programming instructions

80
3300 ICP Technician’s Handbook
10. At [VXWorks Boot], type @, or press the controller Reset button.
Table 4: VxWorks Settings
Prompt Value Note
boot device motfcc Boot device is Network.
processor number 0 Not used.
host name bootHost
file name Boot_Install Boot location and file name.
inet on ethernet (e) IP address and subnet mask (hex) for
controller RTC (for example,
134.199.63.11:ffffff00). Obtain it from your
IT administrator.
inet on backplane (b)
host inet (h) IP address of Installer PC. Used for
software upgrades.
gateway inet (g) IP address of the end user’s default
gateway for the 3300 ICP (must be
outside the DHCP range).
user (u) ftp
ftp password (ftp) ftp
flags (f) 0x0 Uses host inet IP address.
target name (n)
startup script (s)
other (o) motfcc
Time: The system takes approximately 30 minutes to format the hard drive
and install the software.
Tip: If you get an error message see “Installation and Upgrade” on page 183.
After the software install is complete, the file name for all platforms, for
Release 6.0 and later will be: /partition1/Rtc8260.
Tip: Prior to Release 6.0: LX, 250/700-user: /partition1/Rtc8260;
MX: /partition1/Lite200UP; 100-user: /partition1/Lite8260.
Tip: Continue with Step 11 by using the System Administration Tool, or
you can continue by using the Software Installer Tool (see "Installing
System Software on the Controller" on page 71).