Converting a PRI Database on a Universal NSU
To convert a Universal NSU PRI database:
1. Install the IMAT that is on the 3300 software CD-ROM (see page 88).
2. Launch the new IMAT and connect to the Universal NSU.
3. Load the database from your previous IMAT backup.
4. Select PRI 8.2 or NSU 1.4 for your new database version.
5. Convert the database and then save the new database into the NSU.
6. Return to step 2 of the upgrade procedure (see page 72).
Applying a Software Patch
Use the Software Installer Tool to apply a software patch, from Release 4.1
and later. Get the patch (service pack) from Mitel OnLine or from Technical
Support.
To apply a software patch with the Software Installer Tool:
1. Copy the service pack software to a directory on the FTP Server.
2. Launch the Software Installer Tool.
3. In the Identification Screen, enter the following:
- 3300 ICP IP Address or DNS Name of the controller to which you
want to apply the patch
- System Login ID
- System Password
3300 ICP Software Version Universal NSU Database Version
Up to release 3.3 PRI 8.0 or NSU 1.1
Release 4.0 PRI 8.1 or NSU 1.2
Release 4.1, 5.0, or 5.1 PRI 8.2 or NSU 1.3
Release 5.1 PRI 8.2 or NSU 1.4
Release 5.2, 6.0, or 6.1 PRI 8.2 or NSU 1.5
Release 7.0 PRI 8.2 or NSU 1.6
Time: This process takes approximately 15 to 30 minutes including reboot.