Programming instructions

69
Software Procedures
Restore Issue - Music on Hold file size
If you restore a pre-Release 6.0 database, with an embedded music on
hold file larger than 8 MB (for the MX/LX) or 16 MB (for the LX 512 MB),
the file is moved to a temp location and disabled. The following error log is
generated: Embedded System Music On Hold Audio source file size
exceeds allocated space. It has been disabled and placed in a temporary
location: db/temp/system_music_on_hold_tmp.
The relocated file is not backed up and will remain on the hard drive until
a full install is performed of until the file is deleted.
To restore music on hold when it is disabled due to file size:
1. Retrieve the system_music_on_hold_tmp file from db/temp/
2. Reduce the file size.
3. Use the System Audio Files Update form, in the System
Administration Tool, to restore the smaller music on hold audio file.
OR create a new audio file within the size limit.
Software Procedure Requirements:
Installation/Maintenance PC (see page 7 for requirements)
IP address of the 3300 ICP
3300 ICP username and password
3300 ICP software CD
Mitel 3300 ICP Software Installer Tool (for a true upgrade)
3300 ICP Mitel Options Password (see page 11)
Database backup with voice mail messages (see page 61).
Installing the Software Installer Tool
You can install the Software Installer Tool on the Installation/Maintenance
PC, or on its own PC (see page 7 for PC requirements).
Tip: You need a new password if you have purchased new options.
You do not need a new password to change Configuration Options.
Tip: Assign a static IP address to the PC running the Software Installer Tool.