Programming instructions
65
Software Procedures
1. Verify that none of the NSUs are loading. If they are, wait until they
have finished loading. To verify that L0/L1 LEDs are not marching, see
“Universal NSU LED States” on page 347 and “R2 NSU LED States”
on page 348.
2. Log into ESM (using the customer’s username and password), then
click System Administration Tool and select Maintenance
Commands.
3. Issue the dbms stat maintenance command to check if the
DBMS_Initialized flag is ON (look for the line DBMS info:
DBMS_Initialized is ON).
4. Issue the Type *.dr.logfile_1 maintenance command to display the
log file created during the Data Restore. Wait until the checks are
complete, then review the log to ensure there were no errors during
the restore procedure.
5. Issue the message subsystem (me sub) command to check the
programmed NSU links; they should be OPEN. If any programmed
links are in SCAN, check the LINK STATUS LEDs; if the amber LEDs
are marching, the NSUs are writing to the RAM DISK.