Programming instructions
46
3300 ICP Technician’s Handbook
To install the peripheral slot FIM carrier:
1. Attach an anti-static wrist strap.
2. Unpack the peripheral slot FIM carrier and inspect it to ensure that it is
not damaged.
3. Remove the peripheral cabinet front and rear panels.
4. Slide the peripheral slot FIM carrier part-way into the first available slot
from the right.
5. Remove the black plastic dust caps from the fiber optic cable
connectors and from the connector ferrules on the faceplate of the
FIM.
6. Connect the fiber optic cables to the connectors on the FIM via the
fiber optic access port on the rear of the cabinet.
7. Push the peripheral slot FIM carrier fully into the slot and secure it with
the card latch.
8. Remove the anti-static wrist strap.
9. Route the fiber optic cables from the peripheral cabinet to the
SUPERSET HUB.
10. Replace the peripheral cabinet front and rear panels.
Install the SUPERSET HUB Unit
To install the SUPERSET HUB unit:
1. Attach the rubber feet to the base of the unit.
2. If required, secure the mounting brackets to the SUPERSET HUB
case by using the holes for to the selected mounting position, and
install the unit in an equipment rack or mount the unit on a wall.
3. Ensure that the ventilation holes are not blocked.
Tip: The fiber optic cable connectors have a small key that you must align
with a slot on the FIM connectors. Lock each connector into position by
pushing its metal collar forward and clipping it onto the FIM connector.
Tip: The side with the row of RJ-45 connectors faces the front when the unit
is rack-mounted or the top when the unit is wall-mounted. If you are
wall-mounting the unit, use wall anchors appropriate for the wall type, use
#12 screws that are at least 1.5 inches (0.8 cm) long, and ensure that the
screws are not fully tightened so that the unit may be easily removed (without
the use of a tool) for servicing.