Programming instructions
42
3300 ICP Technician’s Handbook
Connecting the Fiber Cable to the Peripheral Cabinet
The fiber optic cable connects the FIM in the controller to the FIM in the
peripheral cabinet.
To connect the fiber optic cable to the FIM in the peripheral cabinet:
1. Route the fiber optic cable through the cable port at the rear of the
peripheral cabinet into the cabinet. Extend the fiber cable
approximately one foot (30 cm) beyond the front of the cabinet.
2. Install a short piece of nylon spiral wrap over the cable at the point
where the cable exits the rear of the cabinet.
3. Close the sliding cable port door. Ensure that the door closes on the
nylon spiral-wrapped section of fiber cable.
4. Remove the plastic dust caps from the fiber optic cable connectors
and the connector ferrules on the FIM faceplate.
5. Plug the fiber connectors into the connector ferrules on the FIM
faceplate.
Checking the Grounding on an AC System
1. Ensure that the power switch (S1) on the power distribution unit (PDU)
is set to the off (0) position and that the switch on the power converter
faceplate is set to the off (0) position.
2. Attach the anti-static wrist strap to your wrist.
3. Slide the installed circuit cards forward slightly so that the card
connectors are not in contact with the cabinet backplane. Leave the
power converter installed.
4. Remove the anti-static wrist strap.
Tip: The fiber connectors have a small key that you must align with a slot on
the FIM connectors. Lock each connector into position by pushing its metal
collar forward and clipping it onto the FIM connector.
CAUTION: Ensure that the grounding meets the require-
ments specified in the Safety Instructions. These instruc-
tions are packaged with each system.
WARNING: DANGER TO PERSONNEL AND/OR
EQUIPMENT DAMAGE COULD RESULT IF THE CABINET IS
NOT POWERED OFF DURING THIS PROCEDURE.