Programming instructions

34
3300 ICP Technician’s Handbook
1. Set up the central DHCP Server with the following options:
- 130 MITEL IP PHONE, string value
- 132 VLAN ID
- 133 Priority, value of 1-6
- 134 Diffserv Code Point, integer value
2. Set up the 3300 ICP DHCP Server with the following options:
- 128 TFTP IP address format
- 129 RTC IP address format
- 130 MITEL IP PHONE, string value
- 132 VLAN ID
- 133 Priority, value of 1-6
- 134 Diffserv Code Point, integer value
3. Program the DHCP server on the 3300 ICP (see procedure above).
Verifying the Operation of the Controller
1. On the Maintenance PC, access the System Administration Tool.
2. In the System Hardware Profile folder, verify that the information in
each of the forms is correct, including the IP address of the E2T for the
LX and 250/700-user system.
3. In Maintenance and Diagnostics, click Alarm Details.
Verify that the following alarms do not appear (if you get an alarm, go
to “Alarms” on page 189):
- E2T Com (not applicable to the MX, CX/CXi, or 100-user controller)
- DSP
4. Connect two IP Phones directly to one of the controller’s Ethernet
ports (for an MX and 100-user controller, only the leftmost port is
functional and you must use a Layer 2 switch for these steps).
5. Program the IP Phones (refer to the System Administration Tool
Online Help for details).
6. Make a call from one phone to the other.
7. Remove the IP Phones from the controller.
Tip: The next four steps are optional.