Programming instructions

27
Installation
3. Select the module in the drop-down list. Choose Dual FIM, Dual
Framer, Quad BRI Framer, or T1/E1 Combo.
4. If you have installed Framer or Combo modules, refer to “Program
Embedded PRI/Q.SIG Trunks”, “Program T1/D4 Trunks”, or “Program
Embedded BRI Trunks” in the Online Help for information.
5. Power down the controller (see page 99).
Connecting the Controller to the Network
This section assumes that the network is already set up, and that there is
a serial connection between the Maintenance PC and the controller.
Setting the Controller RTC IP address (prior to Release 6.0) (page 28).
Programming DHCP (page 29)
Verifying the Operation of the Controller (page 34).
Configuring the Layer 2 Switch (page 35).
Setting the Controller RTC IP address (for Release 6.0 and later)
1. Launch a browser and go to the URL of the 3300 Controller (default
RTC IP address is 192.168.1.2, default gateway 192.168.1.1).
2. The first time you connect, you must install the Mitel Root CA security
certificate (see “Secure Sockets Layer (SSL) and Security Certificate
on page 236).
3. Log into the 3300 ICP ESM using the default username (system) and
password (password).
4. Complete the IP Networking Configuration form to change the IP
addresses.
Tip: See Table 58, “T1 and E1 Connector Pin Allocation,” on page 270 for
Embedded T1/E1 pinout information.
Tip: The Maintenance PC must be on the same subnet as the controller.