Programming instructions
311
Installation Planner
8. Enter a null terminator (0x00) at the end of the hex string under
Binary. The completed dialog box should look like this:
9. Click OK, and then click Close.
10. On the Action menu, select Set Predefined Options.
11. In the Predefined Options and Values dialog box, select the Mitel
Vendor Class from the Option class list. Click Add.
12. In the Option Type dialog box, enter the following:
Field name
What to enter...
Name Mitel Option
Data type String
Code 001
13. Click OK.
14. In the Predefined Options and Values dialog box, select 001 Mitel
Option as the Option name and enter the Mitel Information Data string
with the appropriate values.
15. Enter the Mitel ID string with the appropriate values for <IP address>
and <N>,
id:ipphone.mitel.com;sw_tftp=<IP address>;call_srv=<IP address>;
dscp=<N>;vlan=<N>;l2p=<N>