Programming instructions
306
3300 ICP Technician’s Handbook
Programming E2T via Debug Cable or Secure Telnet
Use the settings in Table 81 below to program the E2T using a debug
cable. The debug (Tapi) cable is an RS-232 serial cable with a PS2
connector at one end and a DB9 connector at the other. For the MXe,
connect to the controller through secure telnet to port 2007.
Tip: Use this section only if you already have a debug cable, and only if you
are directed to do so by Mitel Technical Support.
Table 81: Debug Cable E2T VxWorks Settings
Prompt Value Note
boot device motfcc Boot device is Network.
processor number 0 Not used.
host name bootHost
file name /sysro/E2T8260 Boot location and file name.
inet on ethernet (e) IP address and subnet mask (hex)
for controller E2T (for example,
134.199.63.11:ffffff00). Obtain it
from your IT administrator.
inet on backplane (b)
host inet (h) IP address of controller RTC.
gateway inet (g) IP address of the end user’s default
gateway for the 3300 ICP (must be
outside the DHCP range).
user (u) ftp
ftp password (ftp) @
flags (f) 0x0 Fixed IP address (0x40 used on
E2T for DHCP).
target name (n)
startup script (s)
other (o)