Programming instructions
250
3300 ICP Technician’s Handbook
LSMeasure Tool
Use the LSMeasure Tool to determine the line settings for Loop Start (LS)
trunks that are connected to the Analog Main Board and Analog Option
Board in the controller, or to the Universal ASU.
Refer to Measuring LS Trunk Line Settings in the System Administration
Tool Online Help for detailed instructions and message interpretation.
To launch the LSMeasure Tool:
1. Log into the IP address of the Real Time Controller (RTC).
- To log in through a telnet session, at the "telnet>" prompt, enter
open <IP Address of RTC> 2002
- For RS-232 maintenance session, set the serial port parameters:
Port: COM1
Baud Rate: 9600
Data Bits: 8 data bits
Stop Bit: 1
Parity: None
2. At the −> prompt, type LSMeasure and press Enter.
3. Enter 7 to exit the LSMeasure tool when the tests are complete.