Programming instructions
237
Maintenance
View Logs
This section contains the following:
• Viewing Maintenance or Software Logs (below)
• Collecting System Logs, Release 5.2 and Later (page 238)
• Collecting System Logs, Release 5.1 (page 239)
• Viewing Logs Remotely, TCP/IP Socket Numbers (page 241)
• Viewing Login and Logout Audit Logs (page 242)
Viewing Maintenance or Software Logs
To view maintenance or software logs:
1. Log into the System Administration Tool (see page 8).
2. Click the desired log category (Maintenance or Software).
- To view all the logs in the category, click All Maintenance Logs (or
All Software Logs).
- To view error logs, click Error.
- To view warning logs, click Warning.
- To view information, click Info.
3. To highlight the desired log, move your cursor over it and click once.
The details of the log are displayed in the lower half of the screen.
Table 35: System Reset Causes
Reset Cause Interpretation Root Cause
0x3 Hard reset Unknown reset
0x13 Checkstop reset
(see PPC82XX
manual)
Double bus fault as documented in the
Power PC Manual
0x43 Watchdog reset The watchdog task was unable to write to
the hardware watchdog. A higher priority
task is running or interrupts are disabled.
This is a software problem.
0x83 Power-on reset The system lost AC power.
(Page 1 of 2)