Programming instructions
201
Troubleshooting
Power Over Ethernet
The CXi controller’s Layer 2 switch can provide 120 Watts of power to
802.3af-compliant devices according to the following general rules:
• Up to 16 IP Phones are supported
• Up to four PKMs (PKM12 or PKM48) are supported on Dual Mode IP
phones. Only one PKM can be attached to a set. Multiple PKMs on a
set require an AC adapter.
• Conference units require an AC adapter.
• Port 1 has the highest priority, port 16 the lowest. If the power budget
is exceeded, power will be turned off to the ports, starting with port 16
and ending with port 1, until less than 120 Watts is being consumed.
Digital Service Units (DSU)
BRI Card Alarms and Call Logs
To query alarms or call logs:
1. Log into the BRI maintenance terminal.
2. Enter the Configuration menu item number.
3. Enter the Debug menu item number.
4. Enter the Alarms and Call Log menu item number.
5. Do one of the following:
- To query the alarms, enter the Query Alarms menu item number.
- To query the call logs, enter the Query Call Logs menu item
number.
To clear and reset the call log:
1. Log into the BRI maintenance terminal.
2. Enter the Configuration menu item number.
3. Enter the Debug menu item number.
Tip: Refer to Table 134 on page 377 for a list of all Mitel IP Phones and their
power consumption.
Tip: The CX and CXi controllers do not support Digital Service Units.