Programming instructions

122
3300 ICP Technician’s Handbook
8. Replace the top cover (page 101).
9. Power up the controller (see page 22).
Configure the System for 6000 MAS
To configure the 3300 and APC to support MAS:
1. Power down the 3300 controller.
2. Install the Application Processor Card in the 3300 controller.
3. Install the APC hard drive (on which the software is preloaded) in the
3300.
4. Power-up the 3300.
5. Program the WAN Settings form, in the 3300 System Administration
Tool, to support APC.
6. Launch the secure telnet client.
- Enter open <RTC IP address> using port <2005> (command with
example IP address, open 192.168.1.2 2005).
- Enter the 3300 username and password.
7. Follow on-screen instructions to configure the 6000 MAS and blades.
Refer to the 6000 MAS documentation on Mitel OnLine.
Figure 16: Connecting cables to APC - CXi