Programming instructions

104
3300 ICP Technician’s Handbook
Add or Replace Controller FRUs
This section contains detailed information on adding or replacing the 3300
ICP Field Replaceable Units (FRUs). See page 365 for part numbers.
The section is organized as follows:
“Dual Fiber Interface Module (FIM)” on page 104
“DSP Module” on page 105
“Framer (Dual T1/E1, T1/E1 Combo, Quad BRI)” on page 110
“Echo Canceller” on page 112
“Analog Option Board (MX Controller)” on page 113
“Analog Option Board (CX/CXi Controller)” on page 114.
Dual Fiber Interface Module (FIM)
To add or replace a Dual FIM:
1. Power down the controller (see page 99).
2. Remove the dual FIM from its packaging.
3. Remove a blank module cover. See the Figures on page 15 for slot
locations.
4. Line up the connectors and firmly seat the FIM onto the main board.
5. Secure the Dual FIM module onto the main board using the screws
and lock washers provided.
6. Replace the controller cover and secure it with its screws (see “To
install the LX/700-user controller cover:” on page 100, “To remove the
MX/100-user controller cover:” on page 100, or “Removing/Replacing
CX/CXi/MXe Controller Cover” on page 101).
Tip: See also “Add Controller FRUs” on page 116 and “Replace Controller
FRUs” on page 125.
Tip: You may not install a FIM in a CX or CXi controller.
Tip: Ensure that the type of the optical interface matches that of the mating
unit (820nm single-mode, 1300nm single-mode, or 1300mn multi-mode).