2.2.5 Naming Conventions
• L-band (even)
1571.24 nm, 1572.06 nm, 1572.89 nm, 1573.71 nm, 1574.54 nm, 1575.37 nm, 1576.20 nm, 1577.03 nm,
1577.86 nm, 1578.69 nm, 1579.52 nm, 1580.35 nm, 1581.18 nm, 1582.02 nm, 1582.85 nm, 1583.69 nm,
1584.53 nm, 1585.36 nm, 1586.20 nm, 1587.04 nm, 1587.88 nm, 1588.73 nm, 1589.57 nm, 1590.41 nm,
1591.26 nm, 1592.10 nm, 1592.95 nm, 1593.79 nm, 1594.64 nm, 1595.49 nm, 1596.34 nm, 1597.19 nm,
1598.04 nm, 1598.89 nm, 1599.75 nm, 1600.60 nm, 1601.46 nm, 1602.31 nm, 1603.17 nm, 1604.03 nm.
2.2.5.5 Floating Termination Point
The FTP naming contains three tuples. The first tuple is the EMS name, the second tuple is the ME name,
and the third tuple is the FTP name. The value of the name field in the third tuple is “FTP.” The native
FTP name is a free-format string. However, CTM GateWay/CORBA follows the convention for PTP and
CTP, if applicable.
All Ethernet termination points (TPs) for circuit provisioning on E-series, G-series, ML-series,
CE-100T-8, and FCMR cards are modeled as FTPs. The convention for the FTP values for Ethernet TPs
is as follows:
• For FTPs used in single-card EtherSwitch, CTM uses /rack=1/shelf=1/slot=n/EtherSwitchGroup.
• For FTPs used in multicard EtherSwitch, CTM uses /MulticardEtherSwitchGroup.
• For FTPs used in linear-card EtherSwitch or G-series cards, CTM uses
/rack=1/shelf=1/slot=n/port=m.
• For FTPs used in ML-series cards, CTM uses /rack=1/shelf=1/slot=n/port=m, where m = 0,1.
• To create or report VT tunnel, CTM uses /VTTunnel.
• To create or report VC tunnel, CTM uses /VCTunnel.
• To create VC tunnel for VC3 port grouping and SNCs, CTM uses /rack=1/shelf=1/slot=n/vc4=m,
where n is from 1 to 17 and m is from 1 to 4.
• For VT aggregation point circuits used to create or report VT aggregation point (VAP) circuits, CTM
uses /VAPTP for SONET NEs.
• For low-order aggregation point circuits, CTM uses /LAPTP for SDH NEs.
2.2.5.6 Equipment
For a list of equipment that CTM GateWay/CORBA reports for each NE type, see Appendix D,
“Equipment List for NEs.”
2.2.5.7 Equipment Holder
The TMF defines the EquipmentHolder naming convention. Numbering is done from left to right and
from top to bottom. For example, slot 15 is named /rack=1/shelf=1/slot=15.
For ONS 15xxx NEs, the numbering for EquipmentHolders starts from 0 in the NE. The TMF convention
is to start numbering from 1 for EquipmentHolders. CTM translates EquipmentHolder names. For
example, subslot 1 in slot 0 in the NE is named /rack=1/shelf=1/slot=1/sub_slot=2.
For the ONS 15454 MSTP NEs, shelves are numbered using their unique shelf ID, and not their physical
location attributes, such as rack number and shelf position. For example, slot 1 on an MSTP shelf with
an ID of 7 that is physically located in rack 1, shelf 2 is named /rack=1/shelf=7/slot=1.