User guide
A-24
Cisco Transport Manager Release 9.2 GateWay/CORBA User Guide and Programmer Manual
OL-20937-01
Appendix A Notifications, Fault Management, and Probable Cause Mapping
A.5.4 CTM GateWay/CORBA Mapping—ONS 15216
A.5.4 CTM GateWay/CORBA Mapping—ONS 15216
The following table lists the alarms for the ONS 15216 OADM R2.2.
A.5.4.1 ONS 15216 EDFA2
The following table lists the alarms for the ONS 15216 EDFA2 R2.3 and 2.4.
Table A-18 CTM GateWay/CORBA Alarms for the ONS 15216 OADM R2.2
TMF Mapping NE Native Probable Cause
LOS Add channel signal loss
LOS Drop channel signal loss
EQPT Add and drop channels are out of tolerance
EQPT Add channel signal is too weak and VOA cannot adjust it to match the drop signal
EQPT Power unit A failed
EQPT Power unit B failed
Table A-19 CTM GateWay/CORBA Alarms for the ONS 15216 EDFA2 R2.3, R2.4
TMF Mapping NE Native Probable Cause
UNIDENTIFIED Unknown alarm
EQPT Excessive pump 1 current
EQPT Excessive pump 2 current
EQPT Excessive pump 1 laser temperature
EQPT Excessive pump 2 laser temperature
EQPT Loss of output power
EQPT Loss of input power
EQPT Gain out of range
EQPT Case temperature out of range
EQPT Power unit A failed
EQPT Power unit B failed
EQPT Database backup
EQPT Database restore
EQPT Cutover reset
EQPT Software load
EQPT Software reset