User guide
3-266
Cisco Transport Manager Release 9.2 GateWay/CORBA User Guide and Programmer Manual
OL-20937-01
Chapter 3 Using CTM GateWay/CORBA Interfaces
3.13.3 setTCATPParameter
• PMLocation_T pmLocation
CTM supports PML_NEAR_END_RX and PML_FAR_END_RX.
• PMThresholdType_T thresholdType
CTM supports only TWM_HIGH.
• boolean triggerFlag
Not supported.
• float value
Supported. The NE accepts only integer values. Therefore, CTM rounds off floating point values to
the biggest lower integer. The maximum value supported is 9999999.
• string unit
Not supported.
Throws
globaldefs::ProcessingFailureException
EXCPT_INTERNAL_ERROR - Raised in case of nonspecific EMS internal failure.
EXCPT_INVALID_INPUT - Raised if tpName does not reference a terminationPoint object or at
least one field of tcaParameters is not valid.
EXCPT_ENTITY_NOT_FOUND - Raised when tpName references an object that does not exist.
EXCPT_NE_COMM_LOSS - Raised when communication to the managed element is lost.
LR_STS1_and_AU3_High_Order_VC3
LR_STS3c_and_AU4_VC4
LR_STS12c_and_VC4_4c
LR_STS24c_and_VC4_8c
LR_STS48c_and_VC4_16c
LR_STS192c_and_VC4_64c
CTP PMP_CV_P PML_NEAR_END_RX,
PML_FAR_END_RX
15 min, 24
hour
PMP_ES_P
PMP_SES_P
PMP_UAS_P
PMP_FC_P
PMP_PPJC_PDET PML_NEAR_END_RX 15 min, 24
hour
PMP_NPJC_PDET
PMP_PPJC_PGEN
PMP_NPJC_PGEN
Table 3-10 ONS 15600 SONET TCA TP ParameterName Values (continued)
PTP or CTP pmParameterName Location Interval