User guide
3-145
Cisco Transport Manager Release 9.2 GateWay/CORBA User Guide and Programmer Manual
OL-20937-01
Chapter 3 Using CTM GateWay/CORBA Interfaces
3.9.16 createAndActivateSNCFromUserLabel
vapDestination String You can specify the string (ME name) representing the VAP
destination drop point.
usePortlessTransmux True or false If the value is true, the portless transmux card is used for the circuit.
The NMS provides information for portlessTransmuxMeName,
portlessTransmuxSlot, and isSourceDS3MappedSTS; otherwise, an
INVALID INPUT exception is thrown.
If the value is false, the portless transmux card is not used as the
intermediate point for the end-to-end STS-1 circuit.
portlessTransmuxMeName String ME name containing the high-density portless transmux card, which
is used as a circuit constraint.
Note This attribute is applicable only if usePortlessTransmux is
true.
portlessTransmuxSlot “/rack=1/shelf=1/slot=[
1..6][12..17]”
NMS provides the physical location of the high-density portless
transmux card.
Note Information is required up to the slot level. This attribute is
applicable only if usePortlessTransmux is true.
isSourceDS3MappedSTS True or false Indicates whether the source or destination is DS3 mapped.
Note This attribute is applicable only if usePortlessTransmux is
true.
vcatMemberId Integer, 1 to 256 Used for VCAT SNC creation to identify every VCAT member L1
SNC uniquely. For normal CCAT circuits, this value is ignored, if
specified.
timeSlotRestriction Integer, 1 to 192 for
SONET and 1 to 64 for
SDH.
You can select a specific STS/VC-4 when using autoroute with
constraints. The STS/VC-4 is maintained around the ring. If the same
STS/VC-4 is not available for the entire circuit route, a warning
message is displayed.
includedProtectedME String The parameter must match the name of any ManagedElement which
you have requested to be included in the protected path of an OCHNC
or OCHCC circuit.
For example:
EMS = Cisco Systems/CTM
ManagedElement = myNE
Add the following parameter to configure a routing constraint:
includedProtectedME = myNE
Table 3-4 CTM-Supported Parameters for SNC Creation (continued)
Name Value Description