User guide
3-42
Cisco Transport Manager Release 9.2 GateWay/CORBA User Guide and Programmer Manual
OL-20937-01
Chapter 3 Using CTM GateWay/CORBA Interfaces
3.3.18 getAllEMSSystemClearedAlarms
ONS 15310, ONS 15327, ONS 15454 SONET, ONS 15454 SDH, ONS 15600 SONET, and ONS 15600 SDH
The ONS 15310, ONS 15327, ONS 15454 SONET, ONS 15454 SDH, ONS 15600 SONET, and
ONS 15600 SDH do not send a “clear” for TCA events. TCAs are not reported in the eventList that is
returned by this method.
ONS 15540 and ONS 15530
TCAs are reported in the eventList that is returned by this method. The ONS 15540 sends a “clear” for
TCAs.
Parameters
Throws
globaldefs::ProcessingFailureException
EXCPT_INTERNAL_ERROR - Raised in case of nonspecific EMS internal failure.
EXCPT_UNABLE_TO_COMPLY - Raised when this method is being used by another OSS Client.
EXCPT_TOO_MANY_OPEN_ITERATORS - Raised when the maximum number of iterators reaches 128.
Compliance
CTM-defined.
3.3.18 getAllEMSSystemClearedAlarms
Synopsis
void getAllEMSSystemClearedAlarms(
in notifications::PerceivedSeverityList_T excludeSeverityList,
in unsigned long how_many
out notifications::EventList_T eventList,
out notifications::EventIterator_I eventIt)
raises(globaldefs::ProcessingFailureException);
Description
This interface enables an NMS to request all of the cleared and acknowledged alarms that are for the
EMS itself. Some alarms may be filtered out (excluded) by specifying their severities.
The result of this operation is independent of the filtering set up by the NMS for the notification service.
Name Type Input/Output Description
excludeProbCauseList notifications::ProbableCause
List_T
In List of probable alarm causes to exclude from the
output event list.
excludeSeverityList notifications::PerceivedSeveri
tyList_T
In List of alarm severities to exclude from the output
event list.
how_many unsigned long In Maximum number of alarms to report in the first
batch.
EventList notifications::EventList Out First batch of alarms.
EventIt notifications::EventIterator_I Out Iterator to retrieve the remaining alarms.