User's Guide

Table Of Contents
4-14
Cisco CSS UCS Platform Series User Guide, CPS-UCS-1RU-K9 / CPS-UCS-2RU-K9
Chapter 4 Replacing Hardware Components
Installing or Replacing Server Components
PCIe Slots: Cisco Connected Safety and Security UCS C220
The Cisco Connected Safety and Security UCS C220 server contains a single toolless PCIe riser for
horizontal installation of a PCIe card in slot 1, as shown in Figure 4-8. Ta ble 4-1 describes the PCIe slots
on these risers.
Note PCIe riser and the associated PCIe slot 2 are not supported in this release in the Cisco Connected Safety
and Security UCS C220 server.
Figure 4-8 Rear Panel, Showing PCIe Slots
PSU1PSU1 PSU2PSU2PSU1 PSU2
331712
PCIe 2
PCIe 1
Ta b l e 4-1 PCIe Expansion Slots
Slot Number
Electrical
Lane Width Connector Length Card Length
1
1. This is the supported length because of internal clearance.
1 (on riser 1)
2 (on riser 2)
5
5. Slot 2 is not available in single-CPU configurations.
Not supported in this release.
Replacing a PCIe Card: Cisco Connected Safety and Security UCS C220
Note If you are installing a Cisco UCS Virtual Interface Card, there are prerequisite considerations. See
Special Considerations for Cisco UCS V
irtual Interface Cards” in the Cisco UCS C220 Server
Installation and Service Guide.
Note If you are installing a RAID controller card, see “RAID Controller Considerations” in the Cisco UCS
C220 Server Installation and Service Guide for more information about supported cards and cabling.
To install or replace a PCIe card, follow these steps:
Step 1 Remove a PCIe card (or a blank filler panel) from the PCIe riser:
a. Shut down and power off the server as described in the “Shutting Down and Powering Off the
Server” section on page 4-2.
b. Slide the server out the front of the rack far enough so that you can remove the top cover. You might
have to detach cables from the rear panel to provide clearance.
Card Height
2
2. This is the size of the rear panel opening.
NCSI
3
Support
3. Network Communications Services Interface protocol
Gen-3 x16 x24 extended 1/2 length Full-height
Yes
4
4. Slot 1 can operate when the server is in standby power mode.