User's Guide
Table Of Contents
- Cisco CSS UCS Platform Series User Guide, CPS-UCS-1RU-K9 / CPS-UCS-2RU-K9
- Contents
- Preface
- Overview
- System Overview
- Status LEDs and Buttons
- Supported PSBU Hardware Configurations
- Server and Accessories Part Numbers
- Server Monitoring and Management Tools
- Supported Applications
- Supported Applications
- Installing the Server
- Replacing Hardware Components
- Preparing for Server Component Installation
- Installing or Replacing Server Components
- Server Specifications
- Related Documentation

3-4
Cisco CSS UCS Platform Series User Guide, CPS-UCS-1RU-K9 / CPS-UCS-2RU-K9
Chapter 3 Installing the Server
Preparing for Server Installation
• Ensure that the air-conditioning meets the thermal requirements listed in the “Server
Specifications”.
• Ensure that the cabinet or rack meets the requirements listed in the “Rack Requirements” section on
page 3-4.
• Ensure that the site power meets the power requirements listed in the “Server Specifications”. If
available, you can use an uninterruptible power supply (UPS) to protect against power failures.
Rack Requirements
This section provides the requirements for the standard open racks.
The rack must be of the following type:
• A standard 19-in. (48.3-cm) wide, four-post EIA rack, with mounting posts that conform to English
universal hole spacing, per section 1 of ANSI/EIA-310-D-1992.
• The rack post holes can be square 0.38-inch (9.6 mm), round 0.28-inch (7.1 mm), #12-24 UNC, or
#10-32 UNC when you use the supplied slide rails.
• The minimum vertical rack space per server must be the following:
–
Cisco Connected Safety and Security UCS C220 (1RU): one RU, equal to 1.75 in. (44.45 mm).
–
Cisco Connected Safety and Security UCS C240 (2RU): The minimum vertical rack space per
server must be two RUs, equal to 3.5 in. (88.9 mm).
Equipment Requirements
Cisco Connected Safety and Security UCS C220 (1RU)
The slide rails supplied by Cisco Systems for this server do not require tools for installation. The inner
rails (mounting brackets) are pre-attached to the sides of the server.
Cisco Connected Safety and Security UCS C240 (2RU)
The slide rails supplied by Cisco Systems for this server do not require tools for installation if you install
them in a rack that has square 0.38-inch (9.6 mm), round 0.28-inch (7.1 mm), or #12-24 UNC threaded
holes. The inner rails are pre-attached to the sides of the server.
However, if you install the slide rails in a rack that has #10-32 round holes, a bladed screwdriver is
required to remove the larger square/round mounting pegs from the front of the slide rails.
Slide Rail Adjustment Range
The slide rails for this server have an adjustment range of 24 to 36 inches (610 to 914 mm).