Datasheet
© 2015 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information. Page 5 of 8
Specifications
Table 3 gives specifications of the Cisco Unified IP Conference Phone 8831, Table 4 provides temperature ratings,
and Table 5 lists certifications for the conference station.
Table 3. System Specifications
Category
Specification
Dimensions (H x W x D)
Base: 10.38 x 10.38 x 2.0 in. (15.05 x 26.35 x 5.08 cm)
Control panel: 5.75 x 5.0 x 1.0 in. (14.61 x 12.7 x 2.54 cm)
Microphones: 3.5 x 2.5 x 0.5 in. (8.89 x 6.35 x 1.27 cm)
Charger tray: 6.5 x 4.5 x 0.75 in. (16.51 x 11.43 x 1.90 cm)
Weight
Base 3.50 lbs. (1,587.0 grams)
DCU 0.56 lbs. (253.0 grams)
Wired Microphones 0.15 lbs. (66.8 grams)
Wireless Microphones 0.14 lbs. (64.7 grams)
Charger 0.42 lbs. (191.9 grams)
Display
3.25 x 1.5 in. (8.26 x 3.81 cm); 396 x 162 pixels
Phone casing composition
Polycarbonate acrylonitrile butadiene styrene (ABS) textured plastic
Power requirements
The Cisco Unified IP Conference Phone 8831 is an interoperable IEEE 802.3af PoE (Class 3 device);
48 VDC is required; it can be supplied locally at the desktop using an optional AC-to-DC power supply
(CP-PWR-CUBE-3=). Use of the power supply also requires the use of one of the corresponding AC country
cords listed in Table 7 later in this document.
Use of a power supply (CP-PWR-CUBE-3=) is required when using the Cisco Unified IP Conference Phone 8831
in a daisy-chain configuration.
Table 4. Temperature
Category
Range
Operational temperature
23~104°F (-5°C~40°C)
Nonoperational temperature
shock
-13~158 (-25~70°C)
Temperature altitude
(operational)
77°F (25°C) ambient condition to 9843 ft (3000m)
Temperature altitude
(nonoperational)
Ambient condition to 15,000 ft (4572m)
Temperature humidity
(nonoperational)
95% relative humidity
Note that products with the CE marking in Table 5 indicate compliance with the 2006/95/EC and 2004/108/EC
directives, which include the safety and EMC standards listed.
Table 5. Regulatory Standards Compliance: Safety and EMC
Specification
Description
Regulatory compliance
Products should comply with CE Marking per directives 2004/108/EC and 2006/95/EC
Safety
UL 60950-1 Second Edition Amd 1
CAN/CSA-C22.2 No. 60950-1 Second Edition Amd 1
EN 60950-1 Second Edition A11, A1, A12
IEC 60950-1 Second Edition Amd 1
AS/NZS 60950-1: 2011
GB4943 2011