Specifications
F-8
Cisco TV CDS 2.5 ISA Software Configuration Guide
OL-24788-01
Appendix F Engineering Access Level Pages
CDSM or VVIM Setup
The VVIM and Stream Managers display different configuration, monitoring, reports, and maintenance
pages based on the servers they manage. For example, when CCP is the cache-fill protocol, the VVIM
displays the Configuration Generator page in the Maintenance > Software left-panel menu. The
Configuration Generator page is used to generate the group IDs and server IDs for the Stream Managers
to use in their domains.
Configuring Split-Domain Management
To configure a VVIM that uses split-domain management, set the VVI fields as follows:
• VVI Options—Enabled
• Management System Role—VVI (Vault/Cache) Manager
• Cache Fill Protocol—CCP
Note Content Storage must be enabled to use VVI with split-domain management.
To configure a Stream Manager that uses split-domain management, set the VVI fields as follows:
• VVI Options—Enabled
• Management System Role—Stream Manager
• Cache Fill Protocol—CCP
• VVI (Vault/Cache) Manager VVIM IP—IP address of the VVIM
• Stream Domain Name—Domain name for the Stream Domain
• Streaming Mode—ASI or gigE (Must be set to gigE for the Content Storage feature)
Configuring ISA Regionalization
To configure ISA Regionalization on a Stream Manager, set the CDSM Setup fields as follows:
• Vault Group—Enabled
• Content Storage—Distributed
• VVI—Configure with the following settings:
–
VVI: Enabled
–
Management System Role: Stream Manager
–
Cache Fill Protocols: CCP
–
VVIM IP: IP address of the VVIM
–
Stream Domain Name: name of the Stream Manager
–
Streaming Mode: Gige
To configure ISA Regionalization on a VVIM, set the VVIM Setup fields as follows:
• Vault Group—Enabled
• Content Storage—Distributed
• VVI—Configure with the following settings:
–
VVI: Enabled
–
Management System Role: VVI (Vault/Cache) Manager