Specifications

A-10
Cisco TV CDS 2.5 ISA Software Configuration Guide
OL-24788-01
Appendix A Troubleshooting
General Information and Issues
controller
This is the IP address of the CDSM. There is only one controller line. This line is not needed in the file
for the CDSM, but is used on Vaults and Streamers to point to the CDSM.
mirroring
This controls local mirroring, which is to say this determines the number of copies of a given piece of
content that is stored locally.
partno
This allows the server to identify itself properly to the CDSM. The CDSM can then display the
appropriate server graphic in the GUI and manage the appropriate number of disks, Ethernet ports, and
so on.
mgmtif
The index of the management interface starting at eth0. Typically this remains 0.
ingestif
This parameter is only for Vaults. The index of the ingest interface starting at eth0. Typically this
remains 0 but may have the value of 1 as well.
dbdomsock
This is the “file handle” where the applications address messages intended for the database.
dbnetport
This is the port number where the applications address messages intended for the database.
controlif
The index of the stream control interface starting at eth0. This is an optional configuration that is used
when you want to separate the Setup and Control interface.
Description of the setupfile Settings
This section describes the different parameters of the setupfile file. The setupfile file is located in the
/arroyo/test directory. Some values for the parameters in the setupfile file are set during the initial
configuration (serverid, groupid, streamer vault), others are set by using the CDSM.
Note The localip # line entry has been deprecated. Ignore this line entry.
Required Settings
The following line entries are required in every setupfile file:
serverid #
An identifier that uniquely identifies the server within a group of servers identified by the group ID. See
the “serverid” section on page A-9 for more information.