Specifications
5-3
Cisco TV CDS 2.5 ISA Software Configuration Guide
OL-24788-01
Chapter 5 System Monitoring
System Level Monitoring
Missing or Incorrect Initial IDs
If the CDSM is initially configured incorrectly as a legacy CDS or VVI with central management, then
reconfigured or reinstalled for a VVIM or Stream Manager, the starting IDs for group IDs, server IDs,
and setup IDs need to be changed from the old system to the new system. An alert is added to the Alarms
table to inform you of the situation. Clicking the alert takes you to the Maintain > Software ID
Management page to correct the situation.
System Health
The System Health page provides a top-level view of the overall health of each group in the CDS and
each server in each group.
To view the System Health page, choose Monitor > System Health. See Figure 5-2.
Figure 5-2 System Health Page
The colored boxes for each group on the System Health Monitor page have the following meaning:
• Green—All servers in the group are operating.
• Yellow—One or more servers are not operational, but have not reached any thresholds.
• Red—One or more servers are not operational and have reached a threshold.
The colored boxes for each server on the System Health Monitor page have the following meaning:
• Green—All components are operating.
• Yellow—Some components are not operational, but have not reached a threshold.
• Red—Some components are not operational and have reached a threshold.
The servers can have the following states:
• Online —Server is operational.
• Down—Server is down or database is down.