Specifications

4-72
Cisco TV CDS 2.5 ISA Software Configuration Guide
OL-24788-01
Chapter 4 Configuring the CDS
Array Level Configuration
Note After you have submitted the settings the first time, if you change the Master Vault Group, you
must restart all the Vaults in the old Master Vault Group and the new Master Vault Group for the
changes to take effect. See the “Restarting a Server” section on page 7-11 for more information.
Configuring the Control and Setup IPs
There can only be one IP address designated as the Setup server or Control/Setup server. The Setup
server is another name for the Stream Master IP on the Streamer BMS page. Changing the Setup IP
address (or Control/Setup IP address) changes the Stream Master IP on the Streamer BMS page. See the
“Configuring the Streamer for BMS Connectivity” section on page 4-45 for more information on the
Stream Master IP.
The Control server is used to communicate with Lightweight Stream Control Protocol (LSCP) sessions
or Real Time Streaming Protocol (RTSP) sessions. Each Control server handles up to 10,000 LSCP
sessions. You can use the Stream Master IP (Setup IP) as one of your Control server IP addresses. You
must configure a Control server for each group of up to 10,000 LSCP sessions. For instance, if you have
11,000 LSCP sessions, you need to configure two Control servers. The Control servers are associated
with each Stream Group. There is only one Control server for each Stream Group.
For more information about the Control and Setup servers, see the “Streamer Workflow” section on
page 2-9.
To configure a Control/Setup IP, do the following:
Step 1 Choose Configure > Array Level > Control/Setup IP. The Control/Setup IP page is displayed
(Figure 4-24).
Figure 4-24 Control/Setup IP Page
Step 2
If the CDS is configured for VVI in an ISA environment, the Control/Setup IP page first displays the
Configured VHOs drop-down list. Choose a VHO.