Specifications

4-71
Cisco TV CDS 2.5 ISA Software Configuration Guide
OL-24788-01
Chapter 4 Configuring the CDS
Array Level Configuration
Ignore—Do not use this Vault Group for mirroring or as a backup source of content.
Step 4 Click Submit.
To reset the field, click Reset.
To view the Vault Group mappings, choose the Vault Group from the drop-down list and click Display.
To delete a Vault Group, see the “Configuring Vault Groups” section on page 4-61. When a Vault Group
is deleted, the mapping for the Vault Group is also deleted.
Configuring the Master Vault Group
The Master Vault Group page allows you to select the Vault Group that has the master Vault and the
master IP address. One of the Vaults in the Master Vault Group is designated the master Vault. If the
master Vault fails, another Vault in the Master Vault Group takes over as the master Vault.
The master IP address is configured as the Content Master IP on the Vault BMS page. See the
“Configuring the Vault for BMS Connectivity” section on page 4-50 for more information.
To locate the master Vault in the Master Vault Group, log in to each Vault as root and enter the ifconfig
-a | more command. The master Vault has the virtual IP address (eth0:1) output as follows:
eth0:1 Link encap:Ethernet HWaddr 00:11:00:00:00:00
inet addr:172.22.98.54 Bcast:172.22.99.255 Mask:255.255.254.0
UP BROADCAST RUNNING MULTICAST MTU:1500 Metric:1
Memory:b8820000-b8840000
The slave Vaults do not have the virtual IP address as up.
Note The Master Vault Group page is part of the Vault Groups feature and is displayed only if Vault Groups
is enabled. If VVI is enabled, The Master Vault Group page is displayed only on the VVIM. For more
information, see the “Virtual Video Infrastructure” section on page F-7 and the “Vault Groups” section
on page F-5.
To configure the Master Vault Group, do the following:
Step 1 Choose Configure > Array Level > Master Vault Group. The Master Vault Group is displayed.
Step 2 Check the Master Vault Group check box associated with the Vault Group.
Note If Ingest Steering is enabled and local Vault Groups are configured, the local Vault Groups are
not displayed on the Master Vault Group page. Only national Vault Groups are displayed on the
Master Vault Group page. This is because only national Vault Groups can participate as the
master Vault Group.
If the Content Storage feature is set to Distributed, local Vault Groups that are added to a VHO,
as well as the Stream Groups that are added to the VHO, are displayed on the Master Vault Group
page. Within each VHO, at least one Vault Group or Stream Group must be selected as the
Master Vault Group.
Step 3 Click Submit.