Chapter 7 Management Menu Bar Selection
Serial Port Configuration
Serial Port Configuration
Use MANAGEMENT > Serial Port to navigate to this page.
Use this page to modify configurable serial session properties.
Command Buttons
• Apply: Data is sent to the controller and made to take effect, but not preserved across a power cycle;
these parameters are stored temporarily in volatile RAM.
• Help: Request that the help page be displayed in a new browser window.
Table 7-21 Serial Session Properties
Parameter Description Range
Serial Port Login
Timeout
Specifies the time, in minutes, of
inactivity on a Serial port connection,
after which the controller closes the
connection.
Any numeric value between 0 and 160
is allowed.
The default is 5. A value of 0 disables
the timeout.
Baud Rate (bps) The default baud rate at which the serial
port tries to connect. This is selected
from a pull-down menu.
The available values are 1200, 2400,
4800, 9600, 19200, 38400,57600, and
115200 baud. The Default is 9600 baud.
Character Size The number of bits in a character. 8 (read-only).
Flow Control Whether hardware flow-control is
enabled or disabled.
Disabled (read-only).
Stop Bits The number of Stop bits per character. 1
(read-only).
Parity The parity method used on the Serial
Port.
None (read-only).