Installation Guide

7-7
Cisco x90 Series Content Security Appliances Installation and Maintenance Guide
Chapter 7 Cisco M690 Content Security Management Appliance
Summary of Features
In Table 7-3, read the status and fault LED states together in each row to determine the event that causes
this combination.
Summary of Features
Table 7-4 lists a summary of appliance features.
.
Data/Management port link status Off—No link is present.
Green—Link is active.
Green, blinking—Traffic is present on the active link.
Unit Identification
Off—The unit identification function is not in use.
Blue—The unit identification function is activated.
Table 7-2 Rear Panel LEDs, Definitions of States (continued)
LED Name State
Table 7-3 Rear Power Supply LED States
Green PSU Status LED State Amber PSU Fault LED State Event
Solid on Off 12V main on (main power mode)
Blinking Off 12Vmain off (standby power mode)
Off Off No AC power input (all PSUs present)
Off On No AC power input (redundant supply active)
Blinking Solid on 12V over-voltage protection (OVP)
Blinking Solid on 12V under-voltage protection (UVP)
Blinking Solid on 12V over-current protection (OCP)
Blinking Solid on 12V short-circuit protection (SCP)
Solid on Solid on PSU fan fault/Lock (before OTP)
Blinking Solid on PSU fan fault/Lock (after OTP)
Blinking Solid on Over-temperature protection (OTP)
Solid on Blinking OTP warning
Solid on Blinking OCP warning
Blinking Off 12V main off (CR slave PSU is in sleep mode)
Table 7-4 Cisco M690 Content Security Management Appliance Features
Chassis Two rack-unit (2RU) chassis.
Processors Two E5–2620 v3 processors.
Memory Four 8GB DDR4-2133 DIMM
1
.
Remote Power
Cycle
A Remote Power Cycle can be performed using a
1-Gb dedicated port.