Administrator's Guide
6-16
Cisco Unified Attendant Console Administration and Installation Guide
OL-27293-02
Chapter 6 Configuring and Licensing Cisco Unified Attendant Console Advanced Server
Engineering Menu
• Cisco Unified Attendant BLF Plug-in
Note If you have a resilient system and are logged into the subscriber, the LDAP Plug-in is not available.
To manage logging:
Step 1 Choose Engineering > Logging Management.
The fields in the form are described below:
Field Description
Cisco Unified Attendant Console Advanced server
Main process Log the main process.
CTI process Log the CTI process.
Communication process Log the communication process.
Router process Log the router process.
Database process Log the database process.
Logging path & file name The logging file path and name. For example, C:\Program
Files\Cisco\Attendant Server\Log\ICD.txt.
Number of files The number of log files that can be created in the logging folder. The
default is 10.
Lines per file The number of lines each log file can contain. The default is 10000.
Service logging path & file
name
The service logging file path and name. For example, C:\Program
Files\Cisco\Attendant Server\Log\ICD1.txt.
Cisco Unified Attendant LDAP Plug-in (not available if logged into resilient Subscriber server)
Logging level One of: Detailed (default), Advanced, Minimum, Full.
Logging path & file name The LDAP Plug-in logging file path and name. For example,
C:\Program Files\Cisco\LDAP Plug-in\Log\log.txt.
Number of files The number of log files that can be created in the logging folder. The
default is 10.
Lines per file The number of lines each log file can contain. The default is 200000.
Cisco Unified Attendant CUPS Plug-in
Logging level One of: Detailed (default), Advanced, Minimum, Full.
Logging path & file name The CUPS Plug-in logging file path and name. For example,
C:\Program Files\Cisco\CUPS Plug-in\Log\log.txt.
Number of files The number of log files that can be created in the logging folder. The
default is 10.
Lines per file The number of lines each log file can contain. The default is 10000.
Cisco Unified Attendant BLF Plug-in
Logging level One of: Detailed (default), Advanced, Minimum, Full.
Logging path & file name The BLF Plug-in logging file path and name. For example, C:\Program
Files\Cisco\BLF Plug-in\Log\log.txt.