Installation Guide

6
Cisco UCS C240 M3 NEBS Server Service Note
OL-28629-01
Power Supply Specifications
Power Supply Specifications
This section contains the following topics:
Power Supply LEDs (AC and DC), page 6
650 W AC Power Supply Specifications, page 7
930W DC Power Supply Specifications, page 7
Power Supply LEDs (AC and DC)
Figure 1-4 shows the rear of the 930 W DC power supply, but the LEDs and their states are the same for
the 650 W AC power supply. See Table 1-1 for an explanation of the LED states.
Figure 1-4 930 W, –48 VDC Power Supply (Rear View)
1 Power supply fault LED 3 DC input connector
2 Power supply status LED
930W DC
346116
1
2
3
Table 1-1 Power Supply LEDs, Definition of States
LED Name State
Power supply fault
Off—The power supply is operating normally.
Amber, blinking—An event warning threshold has been reached, but the power
supply continues to operate.
Amber, solid—A critical fault threshold has been reached, which causes the power
supply to shut down (for example, a fan failure or an over-temperature condition).
Power supply status
Off—There is no DC power to the power supply.
Green, blinking—DC power OK; DC output not enabled.
Green, solid—DC power OK; DC outputs OK.