330: How do I install the MultiSite option key?
Incoming MultiSite Call is allowed as a default setting. If the Incoming MultiSite Call is disabled,
it can be turned back on.
Follow the instructions below to turn on Incoming MultiSite Call option using the web interface:
1. Enter the IP address of your codec on a web browser
2. Select Congurations > System Conguration.
3. Select Conference from the menu on the left.
4. In the scroll down menu for IncomingMultisiteCall Mode select Allow.
Follow the instructions below for using the web interface:
1. Enter the IP address of your codec on a web browser
2. Select Maintenance > Option Key.
3. Reboot the codec.
Applies to the following products:
y SX20 Quick Set
y SX80
y Codec C40
y Codec C60
y Codec C90
y MX200
y MX300
y MX200 G2
y MX300 G2
y MX700
y MX800
y EX90
Related questions:
329: Why can I only place point-to-point calls on my codec?
611: Can I run MultiSite on EX and MX video systems?
332: I installed a second PrecisionHD 1080p Camera on my C Series codec, but I am unable
to control it. Why?
To control the second camera you need to use a VISCA cascading cable. The VISCA cascad-
ing cable connects the rst camera to the second camera and can be ordered from Cisco.
You need to congure the video input source to set which camera you should control, when
this particular video input source is active:
1. Login to the codec as admin using SSH (Secure Shell).
2.
To congure the second camera to be connected to video input source 2, run the
following API command:
xConguration Video Input Source 2 CameraControl CameraId: 2
Applies to the following products:
y Codec C40
y Codec C60
y Codec C90
333: I installed a video camera to the video input number 2 on my C90 using component video,
now I am not able to get any video when I activate this source. Why?
A C90 codec can connect up to 12 HD video input sources, but only ve can be active
simultaneously. As default the video input source number 2 is set to be HDMI. You can nd
more information on the video input sources in the Administrator Guide for the C90 codec.
To change this, open the Home menu on the C90 codec and go to: Settings > Administrator
settings > Advanced conguration > Video > Input > Source 2 and set the Connector to YPbPr.
Applies to the following products:
y Codec C90
363: Is transcoding supported for the H.239/dual stream?
No, the H.239/dual stream does not support transcoding. Therefore, the dual stream capability
in an internal MultiSite is restricted by the common denominator.
Applies to the following products:
y SX20 Quick Set
y Codec C20
y Codec C40
y Codec C60
y Codec C90
y MX200
y MX300
y EX60
y EX90
Cisco TelePresence TC Endpoints
D14865.03 TC Endpoints Knowledge Base Articles | APRIL 2015 Copyright © 2011–2013 Cisco Systems, Inc. All rights reserved.
15
Knowledge Base Articles
Contents
Introduction
Questions
Contact
Questions and answers
Appendices
Questions and answers