Release Notes
Interoperability
Cisco TelePresence MCU 5300 Series 4.3(2.30) Software release notes Page 8 of 15
Sony endpoints
Equipment
Version
Results
Sony PCS-G50
2.64
Tested H.323 and H.323 to SIP interworking.
Encrypted interworked calls with this endpoint are not
supported. (CSCtz12733)
Sony PCS-1
3.42
Tested H.323 and H.323 to SIP interworking.
Audio between the MCU and this endpoint is not
supported on interworked calls if “Audio Mode:” setting
on the endpoint is set to either “MPEG4 Audio” or
“Auto”
Sony PCS-HG90
2.22
Tested H.323 and H.323 to SIP interworking.
The MCU should be configured for HD calls only.
MCU does not support sending 60fps to this endpoint.
Sony PCS-XG80
2.31
Tested H.323 and SIP:
FECC is not supported over SIP. (CSCtz01910)
H.323 call to an encryption-required conference results
in an audio-only call. (CSCtz01360)
TANDBERG legacy endpoints
Equipment
Version
Results
TANDBERG Classic
6000
E5.3 PAL
Tested H.323 and H.323 to SIP interworking.
Due to inaccurate timestamps sent by this endpoint, lip
synchronization cannot be guaranteed.
Encryption is not supported if the call bandwidth is
greater than 768k. (CSCtz01365)
TANDBERG 150 MXP
L6.1
Tested H.323 and SIP.
The MCU does not support FECC with this endpoint
when calling using SIP.
Other endpoints
Equipment
Version
Results
Aethra Vega X3
11.2.2
Tested H.323 interoperability.
Due to inaccurate timestamps sent by this endpoint, lip
synchronization cannot be guaranteed.
The MCU does not support SIP with this endpoint.
LifeSize Room 200
4.7.18
Tested: H.323, SIP, H.323 to SIP interworking, and SIP to H.323
interworking.
Interworking is not recommended with this endpoint. It
natively supports SIP and H.323.
Encrypted SIP calls are not supported between the
MCU and this endpoint (CSCtx91859).