User Guide

All RFGW1s configured for this Hub are displayed. Result:
2 Select a single unit to verify.
The selected RFGW1 configuration is displayed. Result:
3 Choose from the following five optional verification techniques.
Manual Verify. Displays the RFGW1 in a browser and uses the GUI
interface to compare configuration data displayed for the selected
RFGW1.
You can use the pull-down menu View=>Selected RFGW in BrowserNote: to
display the currently selected RFGW1.
Auto Verify. Active DB against Created DB. This option collects active
database files from the RFGW1 and compares the contents to the
database files created by the RPU. This process determines if the RFGW1
has been modified since the RPU programmed the unit.
Auto Verify. Active DB against SDV Design File. This option collects the
active database files from the RFGW1 and compares the contents to the
SDV Design File spreadsheet at the time it was last imported into the
RPU. This process determines if the RFGW1 configuration has been
modified and does not match the SDV Design File spreadsheet, or if the
SDV Design File spreadsheet has been modified and imported without
updating the RFGW1.
Auto Verify. Created DB against SDV Design File. This process
determines if the SDV Design File spreadsheet has been modified and
imported since the creation of the RFGW1 database.
28 4035993 Rev A