Initial Provisioning Mode
Initial Provisioning Mode
The RPU can perform initial provisioning for both 48 and 96 channel RFGW1
models. The RPU uses the
MAX QAM column of the Device_Info tab of the SDV
Design File to determine whether the RFGW1 is intended to be provisioned with 48
or 96 channels of data.
Importing Provisioning Parameters
Before starting the provisioning procedure, you must import the Reference Database
and the SDV Design File. Refer to
Importing Reference Database (Phase 1 Step 1c)
(on page
21) and (on page Importing SDV Design File Spreadsheet (Phase 1 Step 1d)
22).
Configure RPU Repository Location (Phase 1 Step 1a)
This feature configures the disk file location where the RPU maintains all of the files
created and referenced by the RPU. The user can locate the RPU repository on a
shared network drive if desired.
To configure the repository, follow the instructions below.
1 Click Set RPU Repository Dir Path and enter the location of the repository path.
See screen below.
2 Click
Test RPU Repository Dir Path.
Result: Indicates whether the RPU repository is present and ready for running
the RPU.
3 Click
and enter desired name in the User Name window. Set User Name
This name is logged in the RPU log file. Result:
4035993 Rev A 19