Release Notes
16
Release Notes for Cisco ONS 15454 SDH Release 4.1.3
OL-4984-01
Caveats
DDTS # CSCea13593
DRI configuration rules require limits on multiple drops. However, in an ONS 15454 SDH DRI topology,
a unidirectional circuit can be created from one ring to another with two drops at the destination node.
This issue will be resolved in Release 5.0.
DDTS # CSCdz90733
PCA traffic can remain down after restoring the incorrect database and then restoring the correct
database to the node. To avoid this issue, exercise care in database restoration. If you accidentally restore
the wrong database, first restore the correct database and check to see if all traffic has returned. If PCA
traffic is still down, you may need to remove and reinsert a fiber or perform a cross connect card reset.
This issue will be resolved in Release 5.0.
DDTS # CSCdz84149
If a user is logged into CTC as a superuser (or other higher level security type), and then another
superuser changes the first user's security level to “retrieve” (or another lower level security type)
without first logging the user out, the lower level user is then still able to perform some actions
authorized only for the original login security level. For example, a “provisioning” level user demoted
to “retrieve” level in this manner can still provision and edit MS-SPRings (BLSRs) while logged into the
current session, though the same user may no longer provision DCCs. To ensure that a user's level is
changed completely, the superuser must log the user out prior to changing the security level. This issue
is under investigation.
DDTS # CSCdz90753
In the Maintenance > Cross Connect Resource Pane, the VT matrix port detail is inconsistent with the
general VT matrix data. This can occur when a 1+1 protection scheme is in place. To avoid confusion,
note that the VT matrix data counts the VTs for both the working and protect card, while the detail data
counts the VTs only for the working card. This issue is under investigation.
DDTS # CSCdz62367
When replacing a failed working E1-42 card in a 1:1 or 1:N protection configuration with the protect
card carrying the switched traffic, bit errors, less than 50ms in duration, are possible on the activated
protection card. This issue is currently under investigation.
DDTS # CSCdy10030
CVs are not positively adjusted after exiting a UAS state. When a transition has been made from counting
UAS, at least 10 seconds of non-SES must be counted to exit UAS. There are no plans to resolve this
issue at this time.
DDTS # CSCdx35561
CTC is unable to communicate with an ONS 15454 SDH that is connected via an Ethernet craft port.
CTC does, however, communicate over an SDCC link with an ONS 15454 SDH that is Ethernet
connected, yielding a slow connection. This situation occurs when multiple nodes are on a single
Ethernet segment and the nodes have different values for any of the following features: