Datasheet
Data Sheet
© 2011 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information. Page 7 of 12
Power Supply 1300W AC 2800W AC 4200W AC 6000 AC 1400W DC with
PEM
2500W AC -
Power Shelf
Output power
combined mode
(PoE)
1333W 2333W 6700W (220V)
3360W (110V)
8700W (220V)
3360W (110V)
3800W (100V) -
Heat dissipation 1568 Btus per hour 2387 Btus per hour 3580 BTU/hr 2720 BTU/hr Data only: 1591
Btus per hour
Data and voice:
2905 Btus per hour
1210 Btus per
hour, per power
supply
Holdup rime 20 ms 20 ms 20 ms 20 ms 4 ms 20 ms
Hot swappable Yes Yes Yes Yes Yes Yes
Additional notes for Table 7 and 8:
●
Output power is per power supply unless otherwise stated
●
Heat dissipation numbers represent the power-conversion losses of the power supply in operation
●
The number of power devices supported will depend on customer configuration
Fan Trays
Each Cisco Catalyst 4500E Series and classic Cisco Catalyst 4500 Series chassis uses a single fan tray for cooling.
All fan trays are composed of independent fans. If one fan fails, the system will continue to operate without a
significant degradation in cooling. The system will detect and notify the user (through LED, command-line interface
[CLI], and SNMP) that a fan has failed and the tray needs to be replaced. Cisco Catalyst 4500E Series fans cannot
be interchanged with classic Cisco Catalyst 4500 Series fans. The classic Cisco Catalyst 4500 Series chassis needs
an E-Series fan tray in order to support the Metro Supervisor Engine 6-E.
Fabric-Redundancy Modules (Cisco WS-C4507R+E, WS-C4510R+E, WS-C4507R-E, and WS-
C4510R-E Only)
The Cisco Catalyst 4500 and 4500E Series redundancy scheme uses removable fabric-redundancy modules on the
passive backplane to switch traffic to the active supervisor engine. There is one fabric-redundancy module per line
card. Fabric-redundancy modules and redundant clocks ship standard with every Cisco Catalyst 4507R+E, 4507R-E,
4510R+E, and 4510R-E chassis. Fabric-redundancy modules cannot be interchanged between the Cisco Catalyst
4507R+E/4510R+E and 4507R-E/4510R-E chassis.
Environmental Conditions
The Cisco Catalyst 4500 and 4500E Series require the following conditions:
●
Operating temperature: 32 to 104ºF (0 to 40ºC)
●
Storage temperature: -40 to 167ºF (-40 to 75ºC)
●
Relative humidity: 10 to 90 percent, noncondensing
●
Operating altitude: -60 to 2000 meters (m)
Regulatory Standards Compliance
Table 9 lists the regulatory standards compliance of the Cisco Catalyst 4500 and 4500E Series.
Table 9. Regulatory Standards Compliance
Specification Standard
Regulatory compliance CE Marking
Safety
●
UL 60950
●
CAN/CSA-C22.2 No. 60950