Release Note
ICM Process Testing In The Staging Environment
Table 3 Sample Test 3-Call Router Fault Tolerance
Test Number:
3
Test Title:
CallRouter Fault Tolerance
Test Purpose:
Verify that CallRouters function in Simplex Mode
Test Setup:
All ICM Services start in full Duplex Mode
Procedure:
1. Stop Router Service on CallRouter A.
2. On CallRouter B, open Router process and check for any messages that indicate Router
A processes are down.
3. Start Router Service on CallRouter A.
4. On Router B check for any messages that indicate that CallRouter A Router and Logger
processes are now OK.
5. Repeat steps 1-4, stopping Router B and validating Simplex Mode on Router A.
Expected Results:
1. CallRouter B indicates that Side A Central Site is down when Router Service
stops on CallRouter A
Pass: Fail:
2. CallRouter B indicates that it is synchronized with CallRouter A when Router
Service starts on CallRouterA.
Pass: Fail:
3. Call Router B indicates that Side A Router and Logger Processes are OK when
Router Service starts on CallRouterA.
Pass: Fail:
4. CallRouter A indicates that Side B Central Site is down when Router Service
stops on CallRouter B.
Pass: Fail:
5. CallRouter A indicates that it is synchronized with CallRouter B when Router
Service starts on CallRouterB.
Pass: Fail:
6. Call Router A indicates that Side B Router and Logger Processes are OK when
Router Service starts on CallRouterB.
Pass: Fail:
7. Call Processing functions as designed when Routers are in Simplex Mode. Pass: Fail:
Passed: (initial)
Failed: (initial)
Reason for Failure:
Remarks:
Release 6.0(0) Staging on Windows 2000
106