Some columns in a report display no data.
Message:
None.
Cause:
IPCC Gateway does not populate all PG-related elds in the Unied ICME database schema.
Since data is not recorded in these database elds, some columns in reports will be empty.
Action:
Because the report concerns an IPCC Gateway deployment, verify that a report column is empty
by consulting the WebView On-line Help for the report.
Abandoned counts do not match between Unified CCE Child and Unified ICME Parent
Symptom:
In Service reports on the Unied ICME parent, the abandoned counts are not the same as the
abandoned counts in Call Type reports on the Unied CCE child.
Message:
None.
Cause:
The conguration for Abandon Wait Time threshold (short calls) does not match between the
Unied ICME parent and the Unied CCE child. See "Differences Between Unied ICME
Parent and Unied CCE Child Reporting".
Action:
Ensure that the congurations are the same on both systems.
Service level metrics do not match between Unified ICME parent and Unified CCE child
Symptom:
Information in Service Reports on the Unied ICME parent for service levels does not match
the information in Call Type Reports for service levels in Unied CCE child.
Message:
None.
Cause: